Our services include manufacture of interference single filters; filter banks made in various design versions (plates, cases, cable boxes, etc.); interference-suppression connectors based on the various types of plugs: RRS, SNC, ONC, RNDT, RGS, OV, and others.
Three types of transformers are available:
Winding methods:
The inductance coils with different types of cores are available:
They are used for hindrance suppression, pulsations smoothing, and alternating current restriction. The cores are made of ferrite.
Envelopment, filling and impregnation of wrapping products with varnish and compounds, as well as coating with paintwork materials, are also available.
Interference filters are designed to work as built-in internal elements of radio-electronic equipment. Filters are installed in electric circuits of direct-current, alternating, pulsating, impulse current for suppression of high-frequency interferences in the range between 0.3 and 1000 MHz. Filters are manufactured according to the climatic category of temperate and cold climate under the state standard GOST 15150. Filters are designed in four versions, on C- and Pi-models of electric circuits.
Capacity, pF | 78…10000 |
Nominal voltage | 100 |
Nominal current, A | 0,2…10 |
Insulation resistance of at least | 20 MOm |
Cut-off frequency, MHz | от 0,3 до 80 |
Operating temperature range, C | from 55 below zero to 85 above zero |
Interference suppression connectors are intended for work as built-in internal elements of radio-electronic equipment. Connectors are installed in electric circuits of direct-current, alternating, pulsating, impulse current for suppression of high-frequency interferences in the range between 0.3 and 1000 MHz. Connectors are manufactured according to the climatic category of temperate and cold climate under the state standard GOST 15150.
Connectors are based on various types of plugs: SNC127, RRS5, 2RMG, RSGE, RSE. Connectors are made with interference filters and case contacts. Connector filters and contacts can be placed in different ways. Connectors are delivered on an order sheet.
Operating temperature range, C | from 55 below zero to 85 above zero |
Insulation resistance between the connector filters as well as between the case and connector filters | of at least 20 meg |
Capacity, pF | 78…10000 |
Nominal voltage, V | 100 |
Nominal current, A | 0,2…10 |
Cut-off frequency, MHz | 0.3 to 80 |
Отдел по гражданской продукции и внешним экономическим связям | |
---|---|
Телефон: | 8-8412-477-888 |
Бесплатный номер: | 8-800-200-47-88 |
E-mail: | 118@electropribor-penza.ru |